The total amount of POHC feed can be site specific based other compounds and potential analytical interferences. For planning purposes only, B3 Systems has created a DRE Calculator.
"In most situations, a dispersion of titanium dioxide (TiO2), DiDp or water-based, is used since it is inert and non-reactive. However some testing requires a specific form of ash."

  

There are two (2) recommended Belden cables that can be used. This first is a Belden 9402. This cable has a non-UV jacket and is recommended for running inside conduit. The second is a Belden 1075A. This cable has a UV jacket and can be run outside of conduit in the elements.
Yes, water droplets carry a charge and can be detected the same as solids particles.
The two values are completely independent of each other. The PM limit is based on the results of a specific EPA test method while the BLD limits are based on the results from your BLD sensor, which are site specific. Please contact B3 Systems directly for become a member of our User Forums for more details and specifics.
Rain, as long as it does not get inside the duct, should not affect the sensor readings under normal circumstances. However we have seen several situations where the rain resulted in process changes and/or physical changes to the sensor operation. These include:
  1. Increased moisture in the process causing condensation in the gas stream
  2. Excessive cooling which resulted in condensation in the process stand-off which lead to contamination and a signal short circuit
  3. Contracting of the duct due to cooling effect and causing buildup on walls to release
  4. Changes to the grounding of the unit
This is a dimensionless relative number that is related to the dust/PM concentration that are passing by the sensor rod. The absolute reading can vary due to particle size and materials ability to carry a charge. Again, this is just a relative number. More information can be obtained in the User Forums.
Your specific requirements always depends on the specific language within the specific rule or your permit. But normally these are not accepted averaging periods. Bag filter monitoring is different than other Operating Parameter Limits (OPL). OPL monitoring can be Rule specific, but most compliance OPLs require valid 1-minute averages to create a 15-minute average. Valid 15-minute averages are used to create valid hour averages and the valid hourly averages are used to create 3, 6 or 12 hour rolling averages. BLDs are monitored continuously (once per second) for alarms due to the fact that most peaks in baghouses can be less than 5 seconds in duration. Monitoring for events less frequently will provide a biased indication of the filter operation.
The answer to this question is YES. We currently provide these services to many of our clients. They can be tailor to your specific needs whether it be a monthly maintenance and response test to a multi-year contract.
Copies of all manuals and documents can be obtained through the website for all valid users. If the document/manual you are seeking is not provide please contact support via email at support@b3systems.com or 919-790-9090.

  

The best option is to always use native material. This way the PM monitor will have the same response as a process upset.